We are using cookies to implement functions like login, shopping cart or language selection for this website. Furthermore we use Google Analytics to create anonymized statistical reports of the usage which creates Cookies too. You will find more information in our privacy policy.
OK, I agree I do not want Google Analytics-Cookies
International Journal of Computerized Dentistry
Login:
username:

password:

Plattform:

Forgotten password?

Registration

Int J Comput Dent 20 (2017), No. 4     15. Dec. 2017
Int J Comput Dent 20 (2017), No. 4  (15.12.2017)

Page 409-421, PubMed:29292414, Language: English/German


Adjustment of retention of all-ceramic double-crown attachments
Schwindling, Franz Sebastian / Rammelsberg, Peter / Krisam, Johannes / Rues, Stefan
Objectives: Double-crown attachments, such as conical crowns (CCs), can retain removable partial prostheses. Digital manufacturing enables the use of innovative materials such as zirconia, and new workflows. The aim of this study was to investigate options for the adjustment of retention forces of all-zirconia CCs.
Materials and methods: Single zirconia primary crowns were produced with convergence angles (α) of 3 and 4 degrees, together with monolithic zirconia secondary crowns (n = 8 for α = 3 degrees; n = 8 for α = 4 degrees). Retention was measured by fitting the crowns with forces F = 12.5 to 100 N, and evaluating the magnitudes of the forces required for loosening (L). L/F ratios were recorded, and the coefficient of friction (µ0) was calculated. To limit the maximum force required for loosening, and to prevent high tensile stresses within the crowns, the width of the occlusal gap between the primary and secondary crowns was limited by the implementation of occlusal stops.
Results: True convergence angles were more conical than expected, by approximately 0.3 degrees. For α = 3 degrees and α = 4 degrees, L/F ratios were 0.308 (SD 0.04) and 0.208 (SD 0.068), respectively. The overall coefficient of static friction was µ0 = 0.113. Maximum retention forces were successfully controlled; the average values were 12.1 N (SD 4.5 N) for zirconia occlusal stops, and 12.8 N (SD 3.3 N) for composite occlusal stops.
Conclusion: The clinically desired L/F ratio of 1/3 was achieved by selecting 3-degree burs for fabrication of all-zirconia CCs. It is possible to limit retention, thereby reducing tensile stress in the circumferential direction in secondary crowns.

Keywords: CAD/CAM, prosthetic dentistry, bioengineering, biomechanics, ceramics, removable dental prosthesis